1

Earth No-mat Coleman 180-day Use

  • Limited Edition
  • Pesticide Quasi-drug

Battery Powered Mosquito Repellents does not require an electrical outlet and is easy to carry.

It is a hypoallergenic type of mosquito repellent that does not have a chemical smell. You can use it anytime, anywhere without an outlet. Safe for babies and pets.

Special site

Where to find

Move to an external site. Please read the contents of each site carefully for prices and service contents, etc., and use them at your own risk.

Product variation

Battery Powered Mosquito Repellents

No fire or heat, no need for outlets and no place to put it, so it can be used safely at home with small children and pets.

Low irritation, odorless type

It is a low irritation and odorless type that does not have a chemical odor.

I know the replacement time

The LED meter clearly shows when to replace the battery and medicine.

Honeycomb structure

Because of the huge volatilization area and high volatilization efficiency unique to the honeycomb structure, the drug volatilizes quickly and works well.

Silent fan

The silent fan is adopted, and the sound of the fan in use is hardly noticeable.

Battery-powered type that can be used in various places without needing an outlet

  • For the outdoors: barbecue, tent
  • In places with few outlets: entrance, veranda
  • For families with children and pets: children's room, living room

adult mosquito

  • Open the battery cover on the bottom of the device, and set the AA battery so that you do not mistake + or-.
    In the case of alkaline batteries, it can be used for about 45 days by using 8 hours a day. The battery needs to be replaced during use. Use of alkaline batteries is recommended, as manganese batteries will reduce the usage time by half.
  • Remove the drug from the bag and push it into the opened instrument until it clicks into place and close the lid. (Do not touch the drug-impregnated part directly.)

    * The drug may be white and solidified, but there is no problem in using it.


    <Common to battery lid (bottom of equipment) and back lid>
    How to open the lid: Hold the bottom of the lid (marked with OPEN) with your finger and slide it upward to remove it.
    How to close the lid: Align the claws on the inside of the lid with the holes in the main body, and slide it downward.
  • When the switch at the top is turned on, the fan rotates and the drug volatilizes. At the same time, the LED meter is activated and the remaining amount of drug and battery is displayed.

About LED meter

  • The yellow lamp shows the remaining amount of drug, and if the lamp blinks during use, replace the drug.
  • The green lamp indicates the battery level, and if the lamp goes out during use, replace the battery.
    (When the battery level lamp goes off, the fan will stop and the drug level lamp will also turn off. For 180 days, it is necessary to replace the AA alkaline battery three times until the end of use of the drug. )

You can use any refill, including Earth No-mat that can be used anywhere, the Electric Earth No-mat, and the Battery-Powered No-Mat.

Find a refillable product for this device

This set contains a 180 day supply of medication.


Please read the "Instruction Manual" attached to the drug carefully before use.
Please keep the "instruction manual" carefully so that you can read it when necessary.

[Precautions on Handling and Storage of Equipment]

  • Do not insert wires or pins into the device. Also, do not touch the appliance with wet hands.
  • Do not disassemble, repair, or modify the equipment as it may cause an accident or failure.
  • Turn off the switch and wipe it off with a dry cloth. Do not use water, detergents or cleaners.
  • Please wipe the dirt and dust of the instrument, please put in a plastic bag and store.

【Something you can not do】

  • Keep out of the reach of children during and after use.
  • Do not insert wires or pins into the device. Also, do not touch the appliance with wet hands.
  • Do not disassemble, repair or modify the equipment as it may cause an accident or failure.
  • Drugs should be placed in the device holding the plastic outer frame. Do not touch the drug impregnated part directly. If the drug component gets on your skin, wash it thoroughly with soap.

【Consulting】

  • If you experience any abnormalities in your body or accidentally ingest the product, immediately inform your doctor that this product contains a Pyrethroid pesticide and seek medical attention.

[Other notes]

  • Be sure to follow the prescribed usage and dose.
  • Do not remove the button battery set in the medicine when using it.
  • Do not block any air intakes or outlets on the device.
  • If using in a closed or narrow room, ventilate occasionally with caution.
  • Take out the used battery and the button battery set in the medicine, and dispose of it according to the regulations of each local government. Use a screwdriver or the like to remove the button battery set in the medicine. Keep the button battery out of the reach of children as it may be accidentally swallowed. If swallowed, please consult a doctor immediately.
  • Dispose of used medicine according to the procedures of your local government.
  • Turn off the switch and wipe it off with a dry cloth. Do not use water, detergents or cleaners.
  • Please wipe the dirt and dust of the instrument, please put in a plastic bag and store.
  • The components volatilize continuously while the power is on, so be sure to turn off the switch when not in use.

【Notes on storage and handling】

  • Do not drop or throw the device, as strong shock or vibration may cause damage.
  • Do not get water on the appliance as it may cause rust or malfunction. If it gets wet, wipe it off immediately.
  • Do not use in places exposed to direct sunlight or high temperatures.
  • Keep in a cool place out of reach of children.
  • When not using it for a long time of 3 to 4 months or more, remove the medicine and battery from the device and keep the medicine sealed with a wrap.
  • Please remove used batteries from the device as soon as possible. The battery may leak.
  • The refills for the Anywhere Earth No-mat can be used with any type of Anywhere Earth No-mat, Earth No-mat battery-operated, or battery-operated No-Mat device.

This product does not fall under the aviation dangerous goods stipulated by the Civil Aeronautics Law.

Product Name Earth No-mat Coleman 180-day Use
Sales name Earth Fan CC
Amount 1 device + 1 drug for 180 days (with 2 AA alkaline batteries)
Country of origin/production area Instruments: China Drugs: Japan
Active Ingredients Transfluthrin 750mg/unit
component Dibutylhydroxytoluene, 1 other ingredient
Effect / effect Elimination or repellent of adult mosquitoes
Duration of effect About 180 days (about 1440 hours in total) by energizing for 8 hours a day
Others Coleman is a trademark of The Coleman Company, Inc.

See the instructions enclosed with the product(PDF: 635KB)

Where to find

Move to an external site. Please read the contents of each site carefully for prices and service contents, etc., and use them at your own risk.

Earth No-mat Coleman 180-day Use

Move to an external site. Please read the contents of each site carefully for prices and service contents, etc., and use them at your own risk.

Campaigns &​ ​
Special Content

  • 温泉ミネラルのベールでポカポカ長続き バスロマン
  • “らく”して“ハッピー”になるお掃除用品 らくハピ
  • 置くだけ簡単、1箱で132万匹(※)捕獲! ダニがホイホイ ダニ捕りシート
  • 『ボトルが上』液残りゼロで香り続く スッキーリ!
  • おくちクチュクチュ♪お口の健康を守る モンダミン
  • 疲労、肩こり、冷え症に 香り弾ける炭酸入浴剤 温泡

View All

Top of page